Dettagli del contatto

Un abito:

1880 Industrial Drive
Libertyville
IL 60048
United States of America

View on Google Maps


ast_info@steris.com

Site Details

Our Libertyville I, Illinois, USA site has the following characteristics:

Site Details

Gamma:

Carrier Type: JS 8900 batch Irradiator (11 Carriers)
Carrier Dimensions: 635 x 939 x 3048 (mm) 25 x 37 x 120 (in)
Notes: Actual dimensions are provided. Usable dimensions may vary depending on product, packaging and/or dose range.

Process Components:

Batch Gamma Irradiation Process Components:

  • Uses a Cobalt-60 continuous irradiator with a source overlap configuration – single pass process
  • Moves product through the gamma irradiation process using an overhead monorail system and pneumatic cylinders to advance the carriers
  • Uses electric scissor lifts to facilitate product loading and unloading
  • Employs barriers to prevent mixing of processed and unprocessed products
  • STERIS AST operates under a quality system that is in compliance with 21 CFR Part 820 and applicable sections of 21 CFR Part 211. In addition, STERIS AST is registered to the ISO 13485:2003 Quality Standard, and adheres to the requirements of ISO 11137-1:2006 (Gamma) and ISO 11135-1:2007 (EO)